NeutrinoResearch Hub

Mass observables · §9

Beta-decay endpoint observable

A non-zero neutrino mass distorts the high-energy end of the β-decay spectrum. Direct kinematic measurements of this distortion give the only model-independent access to the absolute neutrino mass scale.


What it says

m_β is an incoherent sum (using |U_ei|², not U_ei²) of the squared mass eigenvalues weighted by the electron-row mixing — distinct from both the cosmological Σm_ν and the Majorana ⟨m_ββ⟩.

In a tritium-β experiment, the observable is the cut-off energy of the electron spectrum just below the kinematic endpoint E_0 ≈ 18.6 keV. A non-zero m_β shifts the apparent endpoint downward by an amount proportional to m_β.

Why it matters

Unlike cosmological constraints, m_β makes no model assumptions about the early universe. KATRIN currently sets the world's tightest direct bound: m_β < 0.45 eV/c² at 90% C.L., with a final design sensitivity of 0.2 eV.

Future experiments (Project 8 cyclotron-radiation emission spectroscopy, HOLMES microcalorimetry on ¹⁶³Ho) aim for sub-100-meV sensitivity in the next decade.

Derivation sketch

In the allowed-decay approximation, the differential β-decay rate near the endpoint E_0 has the form dN/dE ∝ F(E) p (E_0 − E) √((E_0 − E)^2 − m_ν^2). The neutrino mass enters only through the phase-space factor and bends the spectrum below the endpoint by a tiny amount.

Because the three mass eigenstates are not resolved kinematically (their splittings are ~10^{−3} eV² compared to the experimental resolution of ~1 eV²), the observable is the incoherent sum m_β^2 = Σ_i |U_{ei}|^2 m_i^2.

Achieving sub-eV sensitivity requires (i) a strong source — molecular tritium for KATRIN, atomic tritium for Project 8 — (ii) excellent energy resolution at 18.6 keV (~1 eV for KATRIN), and (iii) tight control of systematics from molecular final-state distributions, energy-loss in the source, and detector backgrounds.

Where it shows up

  • KATRIN — tritium MAC-E filter (current world leader)
  • Project 8 — atomic tritium + cyclotron radiation
  • HOLMES — ¹⁶³Ho microcalorimeter
  • ECHo — similar microcalorimeter approach

Interactive tool

Effective electron-neutrino mass:

m_β = 0.30 eV

KATRIN limit: 0.45 eV (90% C.L.)

E₀ = 18.6 keV electron energy ← toward endpoint → d N / d E (last few eV)

Solid blue: spectrum with current m_β · dashed grey: m_β = 0 reference. The bend below the endpoint is what KATRIN measures.

References

  1. KATRIN Collab., Nature Physics 20, 1112 (2024)  doi:10.1038/s41567-024-02497-x

Related formulas